- Description
Description
Application: Test individual cells of Lead Acid or Nickel-Cadmium or Monoblocs (up to 16Volts) in any general configuration, range 10-6000Ah.
User programmable functions:
• Presets for over 250 battery types .• Low voltage alarm settings .• Low conductivity alarm .• Low conductivity error .• Mode test (push button/automatic start).
Specifications:
Model number | CAD-5000 (Basic Kit) CAD-5200 (Advanced Kit)CAD-5500 (Complete Kit) |
Voltage | 0.8 – 20.0 VDC |
Electrical conductivity | 100 – 19,990 Siemens |
Store test data | 14000 tests stored internally, unlimited with connected USB drive. |
Accuracy | ±2% of test range, voltage and conductivity. |
Voltmeter resolution | 5 mV |
Power requirements | • 7.2V, 2300AH, NiMH • Internal replaceable battery and charger |
Screen | LCD – FSTN 2,619 in x 1,309 in, 128 x 64 pixels, 40 degree viewing angle, contrast ratio 8, green LED backlight. |
Keyboard | Alphanumeric, stainless steel dome, polycarbonate coating, 1,000,000 activations. |
Data transmission | • USB Flash drive (Type A). • USB PC interface (Type B).• Infrared, half-duplex IRDA protocol for printer. |
Scope of environmental activities | 0 to +40C, 95% relative humidity, non-condensing. |
Storage temperatures | -20 to 50C. |
Over voltage protection | • Automatic disconnection • Reverse polarity protection |
Shell material | Santoprene overmold acid-resistant ABS plastic. |